Bardac Drives Products

Optidrive Series AC Drives


Optidrive E2 and E2 SP

A GENERAL-PURPOSE DRIVE WITH ALL-PURPOSE FEATURES

Basic Drive | NEMA 12 (IP55) | Single Phase | Single Phase NEMA 12 (IP55)

  • 3-Phase or Single Phase Motor Controllers
  • Basic or NEMA 12 (IP55)
  • Basic or full featured systems drive
  • Basic or peer-to-peer networking over Ethernet with the dw213 smarty

Basic or loaded, the new E2 is designed to give you the very best in value, performance and ease of use. The innovative design incorporates flexibility, expandability and convenience that will work in many different applications throughout your plant. The basic concept is simple and easy but you have all the options you will need to enhance the drive to a full featured, integrated systems drive.

Download the brochures:

Optidrive Series
Optidrive E
Optidrive E1
Optidrive E2
Optidrive Plus
Optidrive i55
Optidrive VTC
Optidrive Options

Buy Now

optidrive e2

The Basics

contiuous casting
  • Compact packaging
  • Simple mechanical and electrical installation
  • 50°C ambient rating
  • 150% rating for 60 seconds, 175% for 2 seconds
  • Simple 14-parameter basic set up
  • Integral RFI filter option
  • Integral brake transistor, sizes 2 & 3 (100% continuous rated)
  • ModbusRTU serial port
  • Remote keypad and display option
  • OPTISTICK plug in unit for fast up/down load of parameters

Specifications

Output Frequency 0 to 500Hz bottling machine
Supply Options Frequency 48 - 62 Hz
Voltage/Phases 100 - 132 volts max, single phase (0.5 - 1.5HP)
180 - 264 volts max, 1-phase (0.5 - 3HP)
180 - 264 volts max, 3-phase (0.5 - 5HP)
342 - 528 volts max, 3-phase (1 - 15HP)
Output Temperature Operating, -10 to 50°C max, storage, -40 to 60°C
Altitude 0-2000M, derate 1% per 100M above 1000M
Humidity up to 95%, non condensing
Ingress Protection Basic IP20, Optional IP55 (NEMA12)
Control Mode Voltage vector
PWM frequency 4 to 32KHz (effective)
V/Hz ratio Linear
Boost Yes
Stop modes Coast / ramp / DC brake
Skip frequency One point, adjustable frequency band
Setpoint reference 0-10VDC, 4-20mA, 20-4mA, 0-20mA, Keypad, Modbus
Preset speeds 4
PI control Direct & analog input trim
Spin start Starts safely into rotating motor
Accel/Decel 0 - 600 seconds + Ramp stop decel 0 - 600 seconds
Configurable i/o Input 1 Programmable digital input
Input 2 Programmable digital input
Input 3 Configurable analog or digital input
Input 4 Configurable analog or digital input
Output 1 Configurable analog or digital output
Output 2 Normally open relay contact 30VDC 5A, 250VAC 6A
Protection Drive trip Over/under volts, over current, external trip
Motor Overload, over temperature, short circuit, ground fault
Trip memory Last 4 trips stored
 

OPTIDRIVE E2 GENERAL PURPOSE INDUSTRIAL DRIVES

IP20 enclosed industrial drives for general purpose applications

OPTIDRIVE E2 - 115VAC 1-PHASE IN, 230V 3-PHASE OUT

Size Model Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-11005-1H012 6.8" x 3.3" x 4.9" 0.5 2.3
1 ODE2-11010-1H012 6.8" x 3.3" x 4.9" 1.0 4.3
2 ODE2-21015-1H042 8.7" x 4.1" x 5.9" 1.5 5.8

OPTIDRIVE E2 - 230VAC 1-PHASE IN, 230V, 3-PHASE OUT

Size Model Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-12005-1H012 6.8" x 3.3" x 4.9" 0.5 2.3
1 ODE2-12010-1H012 6.8" x 3.3" x 4.9" 1 4.3
1 ODE2-12020-1H012 6.8" x 3.3" x 4.9" 2 7
2 ODE2-22020-1H042 8.7" x 4.1" x 5.9" 2 7
2 ODE2-22030-1H042 8.7" x 4.1" x 5.9" 3 10.5

OPTIDRIVE E2 - 230VAC 3-PHASE IN, 230V, 3-PHASE OUT

3 ODE2-32050-3H042 10.3" x 5.2" x 6.9" 5 14

OPTIDRIVE E2 - 480V, 3-PHASE IN, 460V, 3-PHASE OUT

Size Model Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-14010-3H012 6.8" x 3.3" x 4.9" 1 2.2
1 ODE2-14020-3H012 6.8" x 3.3" x 4.9" 2 4.1
2 ODE2-24020-3H042 8.7" x 4.1" x 5.9" 2 4.1
2 ODE2-24030-3H042 8.7" x 4.1" x 5.9" 3 5.8
2 ODE2-24050-3H042 8.7" x 4.1" x 5.9" 5 9.5
3 ODE2-34075-3H042 10.3" x 5.2" x 6.9" 7.5 14
3 ODE2-34100-3H042 10.3" x 5.2" x 6.9" 10 18
3 ODE2-34150-3H042 10.3" x 5.2" x 6.9" 15 24
 

OPTIDRIVE E2 NEMA12 (IP55) DRIVES

optidrive e2 ip55

NEMA12 (IP55) enclosed industrial drives for harsh, wet and dirty environments

OPTIDRIVE NEMA 12 (IP55) - 115VAC 1-PHASE IN, 230V 3-PHASE OUT

Size Model
(#: N = uNswitched, S = Switched)
Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-11005-1H01# 7.9" x 5.5" x 6.4" 0.5 2.3
1 ODE2-11010-1H01# 7.9" x 5.5" x 6.4" 1 4.3
2 ODE2-21015-1H04# 12.2" x 6.5" x 6.9" 1.5 5.8

OPTIDRIVE NEMA 12 (IP55) - 230VAC 1-PHASE IN, 230V 3-PHASE OUT

Size Model
(#: N = uNswitched, S = Switched)
Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-12005-1H01# 7.9" x 5.5" x 6.4" 0.5 2.3
1 ODE2-12010-1H01# 7.9" x 5.5" x 6.4" 1 4.3
1 ODE2-12020-1H01# 7.9" x 5.5" x 6.4" 2 7
2 ODE2-22020-1H04# 12.2" x 6.5" x 6.9" 2 7
2 ODE2-22030-1H04# 12.2" x 6.5" x 6.9" 3 10.5

OPTIDRIVE NEMA 12 (IP55) - 230VAC 3-PHASE IN, 230V 3-PHASE OUT

Size Model
(#: N = uNswitched, S = Switched)
Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
3 ODE2-32050-3H04# 12.2" x 8.3" x 9.6" 5 14

OPTIDRIVE NEMA 12 (IP55) - 460VAC 3-PHASE IN, 460V 3-PHASE OUT

Size Model
(#: N = uNswitched, S = Switched)
Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-14010-3H01# 7.9" x 5.5" x 6.4" 1 2.2
1 ODE2-14020-3H01# 7.9" x 5.5" x 6.4" 2 4.1
2 ODE2-24020-3H04# 12.2" x 6.5" x 6.9" 2 4.1
2 ODE2-24030-3H04# 12.2" x 6.5" x 6.9" 3 5.8
2 ODE2-24050-3H04# 12.2" x 6.5" x 6.9" 5 9.5
3 ODE2-34075-3H04# 12.2" x 8.3" x 9.6" 7.5 14
3 ODE2-34100-3H04# 12.2" x 8.3" x 9.6" 10 18
 

OPTIDRIVE E2 SP SINGLE PHASE MOTOR CONTROLLER

HVAC fan

The innovative E2 SP Single Phase motor controller uses a unique control algorithm that ensures reliable starting and control. These drives are designed only for use on Shaded Pole (SP) or Permanent Split Capacitor (PSC) type motors in variable torque, fan and centrigugal pump applications. They use high frequency switching to provide near silent running which is most desireable in applications such as commercial and residential HVAC, fume extraction, laboratories and quiet locations.

OPTIDRIVE E2 SP - 115VAC 1-PHASE IN, 115V 1-PHASE OUT - ONLY FOR USE WITH SHADED POLE (SP) OR PERMANENT SPLIT CAPACITOR (PSC) MOTORS

Size Model Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-11005-1H012-01 6.8" x 3.3" x 4.9" 0.5 7
2 ODE2-21007-1H012-01 8.7" x 4.1" x 5.9" 0.75 10.5

OPTIDRIVE E2 SP - 230VAC 1-PHASE IN, 230V 1-PHASE OUT - ONLY FOR USE WITH SHADED POLE (SP) OR PERMANENT SPLIT CAPACITOR (PSC) MOTORS

Size Model Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-12005-1H012-01 6.8" x 3.3" x 4.9" 0.5 4.3
1 ODE2-12010-1H012-01 6.8" x 3.3" x 4.9" 1 7
2 ODE2-22015-1H042-01 8.7" x 4.1" x 5.9" 1.5 10.5
 

OPTIDRIVE E2 SP NEMA12 SINGLE PHASE MOTOR CONTROLLER

NEMA12 (IP55) enclosed Single Phase drives for harsh, wet and dirty environments.

OPTIDRIVE E2 SP NEMA 12 (IP55) - 115VAC 1-PHASE IN, 115V 1-PHASE OUT - ONLY FOR USE WITH SHADED POLE (SP) OR PERMANENT SPLIT CAPACITOR (PSC) MOTORS

Size Model
(#: N = uNswitched, S = Switched)
Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-11005-1H01#-01 7.9" x 5.5" x 6.4" 0.5 7
2 ODE2-21007-1H01#-01 12.2" x 6.5" x 6.9" 0.75 10.5

OPTIDRIVE E2 SP NEMA 12 (IP55) - 230VAC 1-PHASE IN, 230V 1-PHASE OUT - ONLY FOR USE WITH SHADED POLE (SP) OR PERMANENT SPLIT CAPACITOR (PSC) MOTORS

Size Model
(#: N = uNswitched, S = Switched)
Dimensions
(H x W x D)
Heavy Duty Rating
150%, 60 sec overload
HP Amps
1 ODE2-12005-1H01#-01 7.9" x 5.5" x 6.4" 0.5 4.3
1 ODE2-12010-1H01#-01 7.9" x 5.5" x 6.4" 1 7
2 ODE2-22015-1H04#-01 12.2" x 6.5" x 6.9" 1.5 10.5